Oxy-EVO Oxygen Analyser
Mains powered analyser, 100VAC to 240VAC (50/60Hz) autoranging
Precise purging is essential for controlling weld quality, particularly when welding high-alloy, corrosion-resistant materials. Our oxygen analysers can be connected to our controllers for monitoring ID purge quality as part of the programmed weld schedule parameters (except Oxy Smart). The entered oxygen value (in ppm) in the controller is arbitrary. If not specified otherwise, a value of < 30 ppm is generally sufficient at the beginning of the welding process. Welding will not commence until the measured value drops below the programmed threshold. The analysers are calibrated to measure oxygen content in the relevant range for welding <30ppm within +/- 2ppm precision.
Features:
- Simple menu navigation
- For inert gases and mixed gases containing hydrogen
- Measuring cell made of zirconium oxide (maintenance-free)
- 3.5“colour touch panel
- USB interface for storing documentation
- Digital and analogue interface as well as Bluetooth for communication with our controllers and other PLC´s
- Activation and reporting through the analyser and the digital interface
- User adjustable alarm limits and thresholds
- Audible key tones and alarms
- Colour display for figures outside setpoint values
- Multirange 90 – 260 V
Package includes:
- Oxygen analyser
- Power cable
- 3mtr sampling tube including filter and stainless steel probe
- Calibration certificate
- Operation manual
- Plastic case with foam inlay
Oxygen Analyser Oxy-EVO, item No. 1.2.5000